The 220 kV GIS Voltage Transformer is a high‑precision, highly reliable electromagnetic voltage transformer custom‑designed for 220 kV AC power system GIS switchgear. It features an all‑metal, fully enclosed housing and employs ultra‑high‑purity SF₆ gas as the insulating medium. The unit is rigidly connected to the GIS busbar via high‑strength basin‑type insulators. Primarily used to acquire single‑phase voltage signals from the 220 kV system, it provides accurate voltage parameters for grid protection devices, energy metering equipment, and operational monitoring systems. This product meets the compact, intelligent construction requirements of 220 kV GIS substations and fully complies with national standards such as GB/T 20840 and international IEC standards including IEC 61869.
Product Features:
1. A completely redesigned, miniaturized single-phase 220 kV GIS features compact dimensions and lightweight construction, facilitating integrated internal arrangement within the GIS equipment.
2. By employing an ultra-high-gradient insulation structure and a high-precision winding process, the measurement accuracy can reach Class 0.2, while the protection accuracy can achieve Class 0.5, meeting the requirements of high-end applications.
3. The core is constructed from multi‑step‑joint, low‑loss grain-oriented silicon steel laminations, offering excellent excitation characteristics, eliminating the risk of hysteresis saturation, and delivering an exceptionally low voltage waveform distortion.
4. All-metal sealed tank body, with internal insulation using SF₆ gas and no exposed insulating components; resistant to contamination, moisture, and condensation, suitable for demanding operating conditions.
5. Equipped with a multi-stage equalizing shield system, it ensures excellent electric field uniformity, extremely low partial discharge levels, and high long-term insulation reliability.
6. The sealing structure employs a double-seal design, resulting in an extremely low annual SF₆ leakage rate. No gas replenishment is required throughout the equipment’s entire service life, enabling maintenance-free operation.
7. It exhibits strong resistance to overvoltage and short circuits, can withstand system fault transients without damage or false tripping, thereby ensuring the safe and stable operation of the power grid.
8. Low operating noise, minimal temperature rise, and strong mechanical seismic resistance, meeting the dynamic and thermal stability requirements of power systems.
9. The fully enclosed housing is unaffected by altitude, sand and dust, salt spray, acid rain, and extreme temperature fluctuations, making it suitable for a wide range of environments.
10. The enclosure is made of high-strength, corrosion-resistant alloy material and features a special surface treatment, ensuring it remains rust-free, corrosion-resistant, and colorfast even under prolonged outdoor exposure.
Parameter
Model number | JDQXF-66 | JSQ-66 | JDQXF-110 | JSQ-110 | JDQXF-220 | JDQXF-330 | JDQXF-500 | JDQXF-765 | |
Maximum Equipment Voltage (kV) | 72.5 | 126 | 252 | 363 | 550 | 800 | |||
Rated frequency (Hz) | 50/60 | ||||||||
Installation method | Upright/Inverted/Horizontal | ||||||||
Insulation type | SF6 | SF6 or mixed gas | SF6 | ||||||
Rated voltage factor | 1.2 times, consecutive | ||||||||
1.9 times, 8 hours | 1.5 times, 30 seconds | ||||||||
Rated Power-Frequency Withstand Voltage (kV) | 160 | 230 | 460 | 520 | 740 | 975 | |||
Rated Lightning Impulse Withstand Voltage (kV) | 350 | 550 | 1050 | 1175 | 1675 | 2100 | |||
Secondary winding (1a–1n) | Accuracy level | Class 0.2, Class 0.5 | |||||||
Rated Output (VA) | 50 | 100 | 50 | ||||||
Secondary winding (2a–2n) | Accuracy level | Class 0.5, Class 3P | |||||||
Rated Output (VA) | 50 | 100 | 50 | ||||||
Remaining winding (da-dn) | Accuracy level | 3P level | |||||||
Rated Output (VA) | 300 | ||||||||
SF6 rated pressure (20°C) (MPa) | 0.5 | 0.4 | |||||||
SF6 recharging pressure (20°C) (MPa) | 0.45 | 0.35 | |||||||
SF6 leakage rate (%) | <0.05% | ||||||||
SF6 trace moisture content (μL/L) | ≤150 | ||||||||
External dimensions | Height (mm) | 792 | 1000 | 792 | 1000 | 1310 | 1545 | 1725 | 2395 |
Length (mm) | 420 | 795 | 420 | 795 | 666 | 720 | 974 | 1358 | |
Width (mm) | 420 | 795 | 420 | 795 | 666 | 720 | 974 | 1358 | |
Base mounting dimensions | Mounting hole (mm) | 4×φ24 | 4×φ26 | 4×φ24 | 4×φ26 | 4×φ30 | 4×φ26 | 4×φ26 | 8×φ34 |
Hole spacing (mm) | 330×330 | 550×550 | 330×330 | 550×550 | 560×560 | 590×590 | 700×700 | 480×680/ 680×480 | |
Total product weight (kg) | 150 | 460 | 350 | 650 | 950 | 1800 | |||
Quotation Inquiry
Please provide your contact information and specify your requirements, and we will arrange for a dedicated representative to get in touch with you.
JDQXF-220
Product Installation and User Manual Download:
Keywords:
Voltage transformer for GIS
Contact Information
Service Hotline:
Service email: tkhgqscb@163.com
Company Address: No. 11526, Longtan South Road, High-tech Zone, Tai’an City, Shandong Province
Looking forward to working with you.