Detailed Introduction
- Science Fiction 6 Current transformer environmental parameters (customizable for extreme and high-altitude conditions):
Ambient temperature: maximum +40°C, minimum -30°C
Altitude: ≤2000m
Contamination Level: Class D/Class E Contamination
Ice thickness: not exceeding 20 mm
Maximum wind speed: not exceeding 35 m/s
Intended use: Indoor or outdoor
- Science Fiction 6 Current Transformer Product Structure
Science Fiction 6 Current Transformer (CT) Structure (from top to bottom)
| 1. Top: Housing + Primary Winding + Secondary Winding Enclosure: The enclosure completely isolates the internal secondary windings, bushing-type insulators, and other components from the external environment (including wind, rain, contamination, condensation, and small animals). Primary winding: The primary winding is typically a conductive rod that passes through the center of the secondary winding. Secondary winding: Used for metering, measurement, and protection purposes, it converts the primary high current into a secondary low current. | 2. Middle section: Casing (external insulation) Casing: made of high-strength electrical porcelain or silicone rubber, serving as the primary external insulation, supporting the upper section, and sealing the internal cavity. | 3. Bottom: Base + Secondary Junction Box Base: Supports the entire weight of the product and is equipped with mounting holes for connecting the product to the steel bracket. | 4. SF 6 Gas (filling) Function: SF 6 As the primary insulating medium, gas offers an insulation strength far exceeding that of air and possesses self‑healing capabilities. It also enables oil‑free operation, thereby eliminating fire and explosion hazards, while simultaneously facilitating heat dissipation and protecting internal components from oxidation and moisture ingress. Requirement: SF 6 The gas shall have a high purity (≥99.9%), low water content (≤15 μL/L), and reliable sealing under rated pressure (annual leakage rate ≤0.5%). During operation, emissions are strictly prohibited to mitigate the greenhouse effect, and any decomposition products resulting from faults must remain within specified limits. |
- Science Fiction 6 Current transformer parameters (special parameters can be customized)
Project | LVQB-35 | LVQB-110 | LVQB-220 | LVQB-330 | LVQB-500 |
Product Type | Outdoor, single-phase, SF 6 Inverted position | ||||
Rated Voltage (kV) | 35 | 110 | 220 | 330 | 500 |
Maximum Voltage (kV) | 40.5 | 126 | 252 | 363 | 550 |
Rated frequency (Hz) | 50 | ||||
Rated primary current (A) | 100-5000 | 100-5000 | 100-5000 | 0.5-5000 | 100-5000 |
Rated secondary current (A) | 1/5 | ||||
Instrument safety factor | 5/10 | ||||
Accuracy level | 5P, 10P, 0.5, 0.5S, 0.2, 0.2S, TPY | ||||
Operating pressure (MPa) | 0.4 | 0.45 | |||
Alarm pressure (MPa) | 0.35 | 0.35 | 0.35 | 0.35 | 0.4 |
Short-term thermal current / Duration | 40kA/3s | 40kA/3s | 50kA/3s | 63kA/3s | 63kA/3s |
Rated dynamic stability current | 100kA | 100kA | 125kA | 160kA | 160kA |
Rated primary current amplification value | 120% | ||||
Polarity | Negative polarity | ||||
Creepage distance (mm) | 1256 | 3906 | 8593 | 11253 | 17050 |
Arc Flash Distance (mm) | 500 | 1180 | 2200 | 3200 | 4200 |
1.2 µV/√3 partial discharge quantity (pC) | 5 | ||||
A partial discharge quantity (pc) | 10 | ||||
Insulating material | Porcelain | Porcelain / Silicone Rubber | |||
Quotation Inquiry
Please provide your contact information and specify your requirements, and we will arrange for a dedicated representative to get in touch with you.
LVQB-110
Product Installation and User Manual Download:
Keywords:
35–500 kV SF6 Gas-Insulated Current Transformer
Contact Information
Service Hotline:
Service email: tkhgqscb@163.com
Company Address: No. 11526, Longtan South Road, High-tech Zone, Tai’an City, Shandong Province
Looking forward to working with you.
Please let us know what product you need.